High-performance, UL-Listed Notifier Addressable Fire Alarm Systems. Explore 1-loop, 2-loop, 4-loop and 10-loop fire alarm panels, intelligent photoelectric smoke detectors, heat detectors, manual call points (MCP) and control/monitor modules. Ideal for commercial and industrial projects.
Protect commercial premises, industrial plants, residential complexes and infrastructure projects with UL-864 Listed Notifier (Honeywell) Addressable Fire Alarm Systems. Built on FlashScan high-speed communication technology and Onyx Intelligent Sensing algorithms, Notifier fire detection systems deliver pinpoint accuracy, ultra-fast response times and near-zero false alarms.
Whether installing a standalone single-loop panel for a retail store or deploying a networked multi-loop solution across high-rise towers, our scalable Notifier range covers 1-Loop, 2-Loop, 4-Loop and 10+ Loop configurations.
Notifier Fire Alarm Control Panel (FACP) Loop Configurations
1-Loop Addressable Fire Panel (e.g., Notifier NFS-320 / NFS2-320)
• Capacity: Supports 1 Signaling Line Circuit (SLC) loop holding up to 159 addressable detectors and 159 addressable modules (318 total devices per loop).
• Target Projects: Medium-sized commercial buildings, banks, showrooms, schools and single-tenant offices.
• Key Features: Compact all-in-one chassis, built-in power supply, 80-character backlit LCD display and degraded mode operation for uninterrupted safety.
2-Loop Addressable Fire Panel (e.g., Notifier NFS2-640)
• Capacity: 1 loop standard, expandable up to 2 SLC loops supporting up to 636 total addressable devices (318 detectors + 318 modules).
• Target Projects: Multi-story office buildings, manufacturing facilities, hospitals and shopping centers.
• Key Features: Field-programmable, optional Digital Voice Command (DVC) for emergency evacuation audio and high-speed network integration.
4-Loop Addressable Fire Panel (Expandable Systems / Network Nodes)
• Capacity: 2 to 4 loops supporting over 1, 272 addressable field devices.
• Target Projects: IT parks, pharmaceutical plants, university campuses and hotel towers.
• Key Features: Modular loop expansion cards (LCM-320 / LEM-320), intelligent sensitivity adjustments and seamlessly links to central BMS via BACnet/Modbus gateways.
10-Loop / Large-Scale Addressable Fire Panel (e.g., Notifier NFS2-3030 / Inspire Series N16)
• Capacity: 1 to 10 SLC loops managing up to 3, 180 addressable devices per panel. Expandable to 200 nodes via Notifier High-Speed Network (NOTI-FIRE-NET).
• Target Projects: Airports, metro stations, mega industrial complexes, data centers and multi-tower commercial developments.
• Key Features: 640-character large display or touchscreen interface, multi-channel voice evacuation and extensive event history logging.
Compatible Notifier Addressable Field Devices
1. Intelligent Smoke & Thermal Detectors
• Photoelectric Smoke Detector (FSP-851 / FSP-951 Series): Sleek, low-profile optical smoke sensor with drift compensation and remote testing capability.
• Thermal / Heat Detector (FST-851 / FST-951 Series): Fixed temperature (57°C) and Rate-of-Rise thermal detection for dusty or humid environments like kitchens, mechanical rooms and boiler areas.
• Multi-Criteria / Multi-Sensor Detector: Combines photoelectric smoke, thermal and carbon monoxide (CO) sensing for early detection with maximum immunity against nuisance alarms.
• Beam Smoke Detector (FS-OSI-RI): Addressable single-ended reflective beam detector for open-area spaces like warehouses, auditoriums and atrium lobbies.
2. Addressable Manual Call Points (MCP) / Pull Stations
• Notifier Addressable MCP (F/MCP/Glass / NBG-12LX): Dual-action or glass-break manual call points featuring LED status indication and direct address assignment via rotary code switches.
3. Interface Modules & Hooters
• Monitor Module (FMM-1): Connects conventional contact devices (sprinkler flow switches, pressure switches) to the addressable SLC loop.
• Relay Control Module (FRM-1): Provides dry-contact output for controlling fire doors, AHU trips, elevators and access control systems.
• Control / Notification Module (FCM-1): Drives external sounders, strobes and voice evacuation circuits.
• Addressable Hooter Cum Strobe: High-decibel audio-visual alarm devices powered directly from the loop or external 24V DC power supplies.
Technical Specifications Overview
Specification Technical Details
System Standard UL 864 9th / 10th Edition Listed, FM Approved, MEA Approved
Communication Protocol Notifier FlashScan (0.25-second poll per device)
Loop Capacity Options 1 Loop, 2 Loops, 4 Loops, 10 Loops (Expandable up to 3, 180 devices/panel)
SLC Cable Length Up to 12, 500 feet (3, 810 m) per loop using standard unshielded twisted pair
Primary Power Supply 120/230 VAC, 50/60 Hz
Operating Voltage 24 VDC Nominal
Display Options 80-Character LCD, 640-Character LCD or Full-Color Touchscreen
Networking NOTI-FIRE-NET / High-Speed NCM (Wire/Fiber Optic) for up to 200 nodes
Event History Up to 4, 000-event log memory with non-volatile storage
Key Advantages of Choosing Notifier UL-Listed Fire Systems
• Pinpoint Location Identification: Instantly isolates the exact location of smoke or heat detection down to the specific detector address and zone label.
• Pre-Alarm & Maintenance Alerts: Auto-senses dirty detectors and prompts maintenance before false alarms occur.
• BMS & Access Control Integration: Integrates with elevator access control, HVAC/AHU shut-off and gas suppression panels for full facility safety.
• NFPA Compliant: Meets stringent commercial, institutional and industrial fire codes globally.
Request System Design, Testing & Supply
Looking for genuine Notifier UL-Listed Fire Alarm Control Panels, Detectors, MCPs and Modules? Get in touch with our certified fire security engineers for project BOQs, competitive pricing and OEM-certified technical support.