https://www.goldlinesecuritysystems.in
919810287461
INTELLIGEN
ADDRESSABLE FIRE ALARM SYSTEM by HONEYWELL NOTIFIER MARLEY IS LITE COOPER AGNI EDWARD APOLLO RAVEL SIEMENS SCHNEIDER

INTELLIGENT ADDRESSABLE MICROPROCESSOR BASED FIRE ALARM SYSTEM- FIRE PANEL, DETECTOR, MCP, SOUNDER, HOOTERS, INTEGRATION MODULES & LOOP CARDS

Description

NOTIFIER FIRE ALARM CONTROL PANEL IS intelligent Fire Alarm Control Panel (FACP) designed for medium- to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the NFS2-3030 is ideally suited for these applications. The NFS2-3030 is part of the ONYX® Series of products from NOTIFIER. The NFS2-3030 is ideal for virtually any application because it features a modular design that is configured per project requirements. With one to ten Signaling Line Circuits (SLCs), the NFS2-3030 supports up to 3,180 intelligent addressable devices. Information is critical to fire evacuation personnel, and the NFS2-3030’s large 640-character Liquid Crystal Display (LCD) presents vital information to operators concerning a fire situation, fire progression, and evacuation details. A host of other options are available, including single- or multichannel voice; firefighter’s telephone; LED, LCD, or PC-based graphic Annunciations; networking, advanced detection products for challenging environments; wireless fire protection; and many additional options. General Features of Honeywell Notifier Fire Alarm System • Certified for seismic applications when used with the appropriate seismic mounting kit. • Approved for Marine applications when a marine-listed version is used with marine-listed compatible equipment. See DN-60688. • Complies with UL 2572 Mass Notification Systems (NFS2- 3030 version 20 or higher). • One to ten isolated intelligent Signaling Line Circuits (SLC) Style 4, 6 or 7. • Wireless fire protection using SWIFT Smart Wireless Integrated Fire Technology. See DN-60820. • Up to 159 detectors and 159 modules per SLC; 318 devices per loop/3,180 per FACP or network node. – Detectors can be any mix of ion, photo, thermal, or multi sensor; wireless detectors are available for use with the FWSG. – Modules include addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay, wireless modules are available for use with the FWSG. • Large 16 line, 640 character LCD backlit display or use display-less as a network node. • Network options:– High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA). – Standard network for up to 103 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC-EM is used in network paging. • Built-in Alarm, Trouble, Security, and Supervisory relays. • VeriFire® Tools online/offline program option. • With built-in Degraded Mode operation, the system is capable of general alarm if a fire alarm condition is present even if the central processing unit (CPU) fails. • Weekly Occupancy Schedules allow changing sensitivity by time of day and day of week. • EIA-485 annunciators, including custom graphics. • History file with 4000-event capacity in nonvolatile memory, plus separate 1000-event alarm-only file. • Advanced history filters allow sorting by event, time, date, or address. • Alarm Verification selection per point, with automatic counter. • Auto programming and Walk Test reports. • Multiple central station communication options: – Standard UDACT – Internet – Internet/GSM • Positive Alarm Sequence (PAS) Presignal. • Silence Inhibit and Auto Silence timer options. • Field-programmable on panel or on PC, with VeriFire Tools program, also check, compare. • Non-alarm points for lower priority functions. • Remote ACK/Signal Silence/System Reset/Drill via monitor modules. • Up to 1000 powerful Boolean logic equations. • Supports SCS Series smoke control system in both HVAC and FSCS modes. • FM6320 approved Gas Detection System with FMM-4-20 module and any FM listed gas detector. • EIA-232 printer port. • EIA-485 annunciator port. 640-CHARACTER DISPLAY FEATURES • Backlit, 640-character display. • Program keypad: full QWERTY keypad. • Up to nine users, each with a password and selectable access levels. • 11 LED indicators: Power; Fire Alarm; Pre-Alarm; Security; Supervisory; System Trouble; Other Event; Signals Silenced; Point Disabled; CPU Failure; Controls Active. • Membrane Switch Controls: Acknowledge; Signal Silence; Drill; System Reset; Lamp Test. • LCD Display: 640 characters (16 lines x 40 characters) with long-life LED backlight. FLASHSCAN® INTELLIGENT FEATURES • Polls up to 318 devices on each loop in less than two seconds. • Activates up to 159 outputs in less than five seconds. • Multicolor LEDs blink device address during Walk Test. • Fully digital, high-precision protocol (U.S. Patent 5,539,389). • Manual sensitivity adjustment — up to nine levels. • Pre-alarm ONYX intelligent sensing — up to nine levels. • Sensitivity levels: – Ion – 0.5 to 2.5%/foot obscuration. – Photo – 0.5 to 2.35%/foot obscuration. – Laser (VIEW®) – 0.02 to 2.0%/foot obscuration. – Acclimate Plus™ – 0.5 to 4.0%/foot obscuration. – IntelliQuad – 1.0 to 4.0%/foot obscuration. – IntelliQuad™ PLUS – 1.0 to 4.0%/foot obscuration • Drift compensation (U.S. Patent 5,764,142). • Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). • Automatic detector sensitivity testing (NFPA-72 compliant). • Maintenance alert (two levels). • Self-optimizing pre-alarm. • Programmable activation of sounder/relay bases during alarm or pre-alarm. • Read Status displays the level of detector cleanliness. FSL-751 VIEW® (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY • Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). • Addressable operation pinpoints the fire location. • Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. Relay Contact NOTE: CPU2-3030 firmware version 14.0 (and higher) can support LCD-160 on the RDP port, or LCD2-80 in terminal mode, but not both at the same time. CPU2-3030D display or CPU2-3030ND PRN Series Printer NFS2-3030 Sample System Options FAPT-851 FSL-751 FSP-851 FSA-8000 Shown in CAB-C4 with display DVC-EM audio in CA-1 in second tier LCD-160 LCD2-80 Up to 32 Remote Displays EIA-485 EIA-485 SLC Intelligent Loop 3072 annunciator/control points Optional 2048-point UDACT Dual phone lines to Central Station EIA-232 DEVICES ACM/AEM-24AT LED Annunciator LDM-32 Custom Graphics ACM-8R Relay Control NBG-12LX XP6/10 I/O Modules FMM-1 IDC FWSG DN-7070:P • 3/8/17 — Page 3 of 8 FAPT-851 ACCLIMATE PLUS™ LOW-PROFILE INTELLIGENT MULTI-SENSOR • Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based technology; combination photo and thermal technology. • Low-temperature signal at 40°F ± 5°F (4.44°C ± 2.77°C). FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR • Detects all four major elements of a fire (smoke, heat, CO, and flame). • Automatic drift compensation of smoke sensor and CO cell. • High nuisance-alarm immunity. INTELLIGENT FAAST® DETECTORS FSA-5000, FSA-8000, FSA- 20000 AND FSA-20000P • Connects directly to the SLC loop of compatible ONYX series panels. • Provides five event thresholds that can be individually programmed with descriptive labels for control-by-event programming; uses five detector addresses. • Uses patented particle separator and field-replaceable filter to remove contaminants. • Advanced algorithms reject common nuisance conditions • FSA-5000 covers 5,000 square feet through one pipe. • FSA-8000 covers 8,000 square feet through one pipe. • FSA-20000 covers 28,800 square feet through one to four pipes. • FSA-20000P covers 28,800 square feet through one to four addressable pipes. Supports addressable pipes to pinpoint location of alarm events. FCO-851 INTELLIQUAD™ PLUS ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR • Detects all four major elements of a fire. • Separate signal for life-safety CO detection. • Optional addressable sounder base for Temp-3 (fire) or Temp-4(CO) tone. • Automatic drift compensation of smoke sensor and CO cell. • High nuisance-alarm immunity. FMM-4-20 GAS DETECTION MODULE • Interface to industry-standard linear scale 4-20 mA sensors. • Five programmable thresholds. • FM Approved, Class 6320 (Stationary Gas Sensors/ Detectors). SWIFT WIRELESS • Self-healing mesh wireless protocol. • Each SWIFT Gateway supports up to 50 devices: 1 wireless gateway and up to 49 SWIFT devices. • Up to 4 wireless gateways can be installed with overlapping network coverage. RELEASING FEATURES • Ten independent hazards. • Sophisticated cross-zone (three options). • Delay timer and Discharge timers (adjustable). • Abort (four options). VOICE AND TELEPHONE FEATURES • Up to eight channels of digital audio. • 35 watt, 50 watt, 75 watt, and 100/125 watt digital amplifiers (DAA2/DAX series and DS series). • Solid state message generation. • Hard-wired voice control module options. • Firefighter telephone option. • 30- to 120-watt analog amplifiers (AA Series). • Backup tone generator and amplifier option.

Book Appointment

No services available for booking.

Select Staff

AnyBody

Morning
    Afternoon
      Evening
        Night
          Appointment Slot Unavailable
          Your enquiry
          Mobile or Email

          Appointment date & time

          Sunday, 7 Aug, 6:00 PM

          Your Name
          Mobile Number
          Email Id
          Message

          Balinese massage - 60 min

          INR 200

          INR 500

          products False False 08048040910