New Delhi
08048058091
+919811410963
ADDRESSABLE FIRE ALARM SYSTEM by HONEYWELL NOTIFIER MARLEY IS LITE COOPER AGNI EDWARD APOLLO RAVEL SIEMENS SCHNEIDER

INTELLIGENT ADDRESSABLE MICROPROCESSOR BASED FIRE ALARM SYSTEM- FIRE PANEL, DETECTOR, MCP, SOUNDER, HOOTERS, INTEGRATION MODULES & LOOP CARDS

Phone Number

08048058091

Please keep 0 before dialling the number.

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address Goldline Security Systems (HO Delhi) 412, First Floor, Sant Nagar East Of Kailash, New -110065, INDIA ( Near Nehru Place Metro & Iskcon Temple), Phone: +91 9810410961 +91 9811410963

New Delhi, India, 110065

Description

NOTIFIER FIRE ALARM CONTROL PANEL IS intelligent Fire Alarm Control Panel (FACP) designed for medium- to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the NFS2-3030 is ideally suited for these applications. The NFS2-3030 is part of the ONYX® Series of products from NOTIFIER. The NFS2-3030 is ideal for virtually any application because it features a modular design that is configured per project requirements. With one to ten Signaling Line Circuits (SLCs), the NFS2-3030 supports up to 3,180 intelligent addressable devices. Information is critical to fire evacuation personnel, and the NFS2-3030’s large 640-character Liquid Crystal Display (LCD) presents vital information to operators concerning a fire situation, fire progression, and evacuation details. A host of other options are available, including single- or multichannel voice; firefighter’s telephone; LED, LCD, or PC-based graphic Annunciations; networking, advanced detection products for challenging environments; wireless fire protection; and many additional options. General Features of Honeywell Notifier Fire Alarm System • Certified for seismic applications when used with the appropriate seismic mounting kit. • Approved for Marine applications when a marine-listed version is used with marine-listed compatible equipment. See DN-60688. • Complies with UL 2572 Mass Notification Systems (NFS2- 3030 version 20 or higher). • One to ten isolated intelligent Signaling Line Circuits (SLC) Style 4, 6 or 7. • Wireless fire protection using SWIFT Smart Wireless Integrated Fire Technology. See DN-60820. • Up to 159 detectors and 159 modules per SLC; 318 devices per loop/3,180 per FACP or network node. – Detectors can be any mix of ion, photo, thermal, or multi sensor; wireless detectors are available for use with the FWSG. – Modules include addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay, wireless modules are available for use with the FWSG. • Large 16 line, 640 character LCD backlit display or use display-less as a network node. • Network options:– High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA). – Standard network for up to 103 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC-EM is used in network paging. • Built-in Alarm, Trouble, Security, and Supervisory relays. • VeriFire® Tools online/offline program option. • With built-in Degraded Mode operation, the system is capable of general alarm if a fire alarm condition is present even if the central processing unit (CPU) fails. • Weekly Occupancy Schedules allow changing sensitivity by time of day and day of week. • EIA-485 annunciators, including custom graphics. • History file with 4000-event capacity in nonvolatile memory, plus separate 1000-event alarm-only file. • Advanced history filters allow sorting by event, time, date, or address. • Alarm Verification selection per point, with automatic counter. • Auto programming and Walk Test reports. • Multiple central station communication options: – Standard UDACT – Internet – Internet/GSM • Positive Alarm Sequence (PAS) Presignal. • Silence Inhibit and Auto Silence timer options. • Field-programmable on panel or on PC, with VeriFire Tools program, also check, compare. • Non-alarm points for lower priority functions. • Remote ACK/Signal Silence/System Reset/Drill via monitor modules. • Up to 1000 powerful Boolean logic equations. • Supports SCS Series smoke control system in both HVAC and FSCS modes. • FM6320 approved Gas Detection System with FMM-4-20 module and any FM listed gas detector. • EIA-232 printer port. • EIA-485 annunciator port. 640-CHARACTER DISPLAY FEATURES • Backlit, 640-character display. • Program keypad: full QWERTY keypad. • Up to nine users, each with a password and selectable access levels. • 11 LED indicators: Power; Fire Alarm; Pre-Alarm; Security; Supervisory; System Trouble; Other Event; Signals Silenced; Point Disabled; CPU Failure; Controls Active. • Membrane Switch Controls: Acknowledge; Signal Silence; Drill; System Reset; Lamp Test. • LCD Display: 640 characters (16 lines x 40 characters) with long-life LED backlight. FLASHSCAN® INTELLIGENT FEATURES • Polls up to 318 devices on each loop in less than two seconds. • Activates up to 159 outputs in less than five seconds. • Multicolor LEDs blink device address during Walk Test. • Fully digital, high-precision protocol (U.S. Patent 5,539,389). • Manual sensitivity adjustment — up to nine levels. • Pre-alarm ONYX intelligent sensing — up to nine levels. • Sensitivity levels: – Ion – 0.5 to 2.5%/foot obscuration. – Photo – 0.5 to 2.35%/foot obscuration. – Laser (VIEW®) – 0.02 to 2.0%/foot obscuration. – Acclimate Plus™ – 0.5 to 4.0%/foot obscuration. – IntelliQuad – 1.0 to 4.0%/foot obscuration. – IntelliQuad™ PLUS – 1.0 to 4.0%/foot obscuration • Drift compensation (U.S. Patent 5,764,142). • Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). • Automatic detector sensitivity testing (NFPA-72 compliant). • Maintenance alert (two levels). • Self-optimizing pre-alarm. • Programmable activation of sounder/relay bases during alarm or pre-alarm. • Read Status displays the level of detector cleanliness. FSL-751 VIEW® (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY • Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). • Addressable operation pinpoints the fire location. • Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. Relay Contact NOTE: CPU2-3030 firmware version 14.0 (and higher) can support LCD-160 on the RDP port, or LCD2-80 in terminal mode, but not both at the same time. CPU2-3030D display or CPU2-3030ND PRN Series Printer NFS2-3030 Sample System Options FAPT-851 FSL-751 FSP-851 FSA-8000 Shown in CAB-C4 with display DVC-EM audio in CA-1 in second tier LCD-160 LCD2-80 Up to 32 Remote Displays EIA-485 EIA-485 SLC Intelligent Loop 3072 annunciator/control points Optional 2048-point UDACT Dual phone lines to Central Station EIA-232 DEVICES ACM/AEM-24AT LED Annunciator LDM-32 Custom Graphics ACM-8R Relay Control NBG-12LX XP6/10 I/O Modules FMM-1 IDC FWSG DN-7070:P • 3/8/17 — Page 3 of 8 FAPT-851 ACCLIMATE PLUS™ LOW-PROFILE INTELLIGENT MULTI-SENSOR • Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based technology; combination photo and thermal technology. • Low-temperature signal at 40°F ± 5°F (4.44°C ± 2.77°C). FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR • Detects all four major elements of a fire (smoke, heat, CO, and flame). • Automatic drift compensation of smoke sensor and CO cell. • High nuisance-alarm immunity. INTELLIGENT FAAST® DETECTORS FSA-5000, FSA-8000, FSA- 20000 AND FSA-20000P • Connects directly to the SLC loop of compatible ONYX series panels. • Provides five event thresholds that can be individually programmed with descriptive labels for control-by-event programming; uses five detector addresses. • Uses patented particle separator and field-replaceable filter to remove contaminants. • Advanced algorithms reject common nuisance conditions • FSA-5000 covers 5,000 square feet through one pipe. • FSA-8000 covers 8,000 square feet through one pipe. • FSA-20000 covers 28,800 square feet through one to four pipes. • FSA-20000P covers 28,800 square feet through one to four addressable pipes. Supports addressable pipes to pinpoint location of alarm events. FCO-851 INTELLIQUAD™ PLUS ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR • Detects all four major elements of a fire. • Separate signal for life-safety CO detection. • Optional addressable sounder base for Temp-3 (fire) or Temp-4(CO) tone. • Automatic drift compensation of smoke sensor and CO cell. • High nuisance-alarm immunity. FMM-4-20 GAS DETECTION MODULE • Interface to industry-standard linear scale 4-20 mA sensors. • Five programmable thresholds. • FM Approved, Class 6320 (Stationary Gas Sensors/ Detectors). SWIFT WIRELESS • Self-healing mesh wireless protocol. • Each SWIFT Gateway supports up to 50 devices: 1 wireless gateway and up to 49 SWIFT devices. • Up to 4 wireless gateways can be installed with overlapping network coverage. RELEASING FEATURES • Ten independent hazards. • Sophisticated cross-zone (three options). • Delay timer and Discharge timers (adjustable). • Abort (four options). VOICE AND TELEPHONE FEATURES • Up to eight channels of digital audio. • 35 watt, 50 watt, 75 watt, and 100/125 watt digital amplifiers (DAA2/DAX series and DS series). • Solid state message generation. • Hard-wired voice control module options. • Firefighter telephone option. • 30- to 120-watt analog amplifiers (AA Series). • Backup tone generator and amplifier option.

Other Products

view all

Notifier N16 Fire Alarm Control Panel UL 1Loop 2 Loop 3 Loop 4 Loop and up to 10 Loop Capacity

NOTIFIER INSPIR N16 Fire Alarm Control Panel (FACP) by Honeywell, the industry’s most advanced, scalable and UL-listed fire protection solution. Engineered with a highly adaptable modular architecture, the Notifier N16 seamlessly scales to fit facilities of any size, offering flexible configurations ranging from a base 1 Loop and 2 Loop setup, seamlessly expanding to 3 Loop, 4 Loop and up to a massive 10 Loop capacity. By utilizing the SLM-318 (Signaling Line Module), each loop supports up to 318 intelligent addressable devices, allowing a fully expanded panel to protect up to 3,180 points on a single node. To perfectly match your project requirements, this Connected Life Safety Services (CLSS) integrated panel is available in several core model part numbers, including the pre-configured N16E (black cabinet) and N16E-R (red cabinet), which arrive out-of-the-box as a 1-loop system with a vivid 10-inch touchscreen display. For enterprise-level networking and high-capacity installations, specifiers can select the CPU-N16LD (N16x with display), the CPU-N16LND (network node without display), or the CPU-16-RTO chassis specifically designed for retrofit applications. The system's most cost-effective advantage is its software-defined scalability; facility managers can upgrade a standard N16e persona to the full 10-loop N16x persona instantly using the N16-XUPG software license, eliminating the need for expensive hardware rip-and-replaces. Supported by robust, customizable power solutions like the PMB-AUX and PMB-AUX-RTO addressable power supplies, the Notifier N16 utilizes the ultra-fast FlashScan® protocol to deliver unmatched diagnostic speed. Whether you are securing a multi-building campus, a high-rise, or a complex industrial warehouse, the Notifier N16 FACP provides the ultimate future-proof, NFPA-compliant fire alarm system.

Notifier Self Test Detectors New Technology UL Listed Smoke Detectors FSP-951-SELFT FSP-951T-SELFT

Inspecting hard to reach or occupied spaces doesn't have to be a headache anymore. Paired with the Honeywell NOTIFIER INSPIRE™ panel and CLSS gateway, we are proud to offer NOTIFIER Self Test Detectors the very first UL approved detectors that can be tested automatically! Why this is a game changer for your facility: • Remote Testing: Test each device instantly at the touch of a button. • Zero Disruption: Removes the need for ladders, lifts, or full physical access to difficult, high ceiling, or highly secure occupied spaces. • Lightning Fast: Drastically reduces the time it takes to conduct a thorough, compliant inspection. Upgrade your building's life safety with the NOTIFIER INSPIRE™ N16E panel and experience the future of automated, stress free compliance. Revolutionary NOTIFIER Self Test Detectors: Compliance at the Touch of a Button A fire alarm system is only as good as its last inspection, but routine testing often brings operations to a halt. The NOTIFIER INSPIRE™ N16E panel integrates seamlessly with NOTIFIER Self Test Detectors—the industry’s first UL approved smoke detectors that can be tested automatically. By connecting the N16E panel with Honeywell’s CLSS gateway, facility managers and integrators can enable remote testing. This means each device on your loop can be fully tested at the touch of a button. The Self Test Advantage: • Eliminate Access Barriers: Completely removes the need for physical access to difficult to reach detectors in high atriums, elevator shafts, or secure occupied spaces. • Reduce Inspection Times: What used to take days of manual testing with canned smoke and ladders can now be conducted thoroughly and drastically faster, minimizing labor costs. • Uninterrupted Operations: Keep your business, hospital, or school running smoothly without technicians disrupting occupied rooms. Combined with the 1 to 3 loop scalability of the Inspire N16E, these self testing capabilities deliver an unmatched return on investment by drastically reducing your ongoing maintenance and inspection overhead. 📞 Contact us today to learn how much time and money self testing detectors can save your facility!

Honeywell Notifier N16E Next-Gen Fire Alarm Panel Expandable 1 to 3 Loops for Commercial Fire Safety

When it comes to commercial fire safety, facility managers and integrators need a system that is intuitive, compliant and ready to scale. The Honeywell Notifier Inspire N16E is a next-generation Fire Alarm Control Panel (FACP) designed to deliver robust, cyber-secure and easily managed life safety protection for a wide range of facilities. Unmatched Scalability: 1 to 3 SLC Loops The Notifier N16E is engineered to grow with your building. It ships pre-configured with a single Signaling Line Module (SLM-318), supporting up to 318 intelligent addressable devices. Need more coverage? The N16E enclosure includes two expansion slots, allowing you to seamlessly add two additional loop cards. Fully expanded to 3 loops, the panel supports up to 954 devices, making it the perfect fit for small facilities that anticipate future expansions, modular additions or campus growth. Key Features & Innovations • 10-Inch HD Touchscreen Interface: Gone are the days of confusing button layouts. The N16E features a bright, responsive 10-inch display utilizing color-coded icons. During an emergency or routine maintenance, operators can instantly identify active alarms, troubles and supervisory counts. • Connected Life Safety Services (CLSS): The N16E integrates seamlessly with Honeywell’s CLSS cloud platform. This allows building owners and technicians to remotely monitor system health, access real-time event logs and generate compliance reports directly from a mobile device or workstation. • Self-Test Detector Compatibility: Maintenance is significantly streamlined. The N16E is fully compatible with Notifier’s Self-Test detectors, which automatically verify smoke and heat functionality without requiring technicians to manually test every single device with canned smoke. • Industry-Leading Speed & Capacity: Every input and output device on the loop is sampled in less than two seconds, ensuring immediate detection and rapid response times when seconds matter most. • Backward Compatibility: Designed with retrofits in mind, the N16E allows for easy upgrades from legacy systems, saving on costly full-system rip-outs while modernizing your building’s fire defense. The Smart Choice for Life Safety The Honeywell Notifier Inspire N16E bridges the gap between hardware reliability and modern software intelligence. By reducing manual maintenance requirements and offering comprehensive cloud visibility, the N16E doesn't just alert you to fires—it actively reduces your total cost of ownership while keeping occupants safe. Reach out to our certified fire alarm technicians today to design, install or upgrade your facility with the Notifier Inspire N16E panel. Notifier N16 Supports all FSP-951, FAPT-951 and FST-951 Smoke Detectors in Backward Compatibility Even if they are already installed in the building.