NOTIFIER FIRE ALARM CONTROL PANEL IS intelligent Fire Alarm Control Panel (FACP) designed for medium- to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the NFS2-3030 is ideally suited for these applications. The NFS2-3030 is part of the ONYX® Series of products from NOTIFIER. The NFS2-3030 is ideal for virtually any application because it features a modular design that is configured per project requirements. With one to ten Signaling Line Circuits (SLCs), the NFS2-3030 supports up to 3,180 intelligent addressable devices. Information is critical to fire evacuation personnel, and the NFS2-3030’s large 640-character Liquid Crystal Display (LCD) presents vital information to operators concerning a fire situation, fire progression, and evacuation details. A host of other options are available, including single- or multichannel voice; firefighter’s telephone; LED, LCD, or PC-based graphic Annunciations; networking, advanced detection products for challenging environments; wireless fire protection; and many additional options.
General Features of Honeywell Notifier Fire Alarm System
• Certified for seismic applications when used with the appropriate seismic mounting kit.
• Approved for Marine applications when a marine-listed version is used with marine-listed compatible equipment. See DN-60688.
• Complies with UL 2572 Mass Notification Systems (NFS2- 3030 version 20 or higher).
• One to ten isolated intelligent Signaling Line Circuits (SLC) Style 4, 6 or 7.
• Wireless fire protection using SWIFT Smart Wireless Integrated Fire Technology. See DN-60820.
• Up to 159 detectors and 159 modules per SLC; 318 devices per loop/3,180 per FACP or network node.
– Detectors can be any mix of ion, photo, thermal, or multi sensor; wireless detectors are available for use with the FWSG.
– Modules include addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay, wireless modules are available for use with the FWSG.
• Large 16 line, 640 character LCD backlit display or use display-less as a network node.
• Network options:– High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA).
– Standard network for up to 103 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC-EM is used in network paging.
• Built-in Alarm, Trouble, Security, and Supervisory relays.
• VeriFire® Tools online/offline program option.
• With built-in Degraded Mode operation, the system is capable of general alarm if a fire alarm condition is present even if the central processing unit (CPU) fails.
• Weekly Occupancy Schedules allow changing sensitivity by time of day and day of week.
• EIA-485 annunciators, including custom graphics.
• History file with 4000-event capacity in nonvolatile memory, plus separate 1000-event alarm-only file.
• Advanced history filters allow sorting by event, time, date, or address.
• Alarm Verification selection per point, with automatic counter.
• Auto programming and Walk Test reports.
• Multiple central station communication options:
– Standard UDACT
– Internet
– Internet/GSM
• Positive Alarm Sequence (PAS) Presignal.
• Silence Inhibit and Auto Silence timer options.
• Field-programmable on panel or on PC, with VeriFire Tools program, also check, compare.
• Non-alarm points for lower priority functions.
• Remote ACK/Signal Silence/System Reset/Drill via monitor modules.
• Up to 1000 powerful Boolean logic equations.
• Supports SCS Series smoke control system in both HVAC and FSCS modes.
• FM6320 approved Gas Detection System with FMM-4-20 module and any FM listed gas detector.
• EIA-232 printer port.
• EIA-485 annunciator port.
640-CHARACTER DISPLAY FEATURES
• Backlit, 640-character display.
• Program keypad: full QWERTY keypad.
• Up to nine users, each with a password and selectable
access levels.
• 11 LED indicators: Power; Fire Alarm; Pre-Alarm; Security; Supervisory; System Trouble; Other Event; Signals Silenced; Point Disabled; CPU Failure; Controls Active.
• Membrane Switch Controls: Acknowledge; Signal Silence; Drill; System Reset; Lamp Test.
• LCD Display: 640 characters (16 lines x 40 characters) with long-life LED backlight.
FLASHSCAN® INTELLIGENT FEATURES
• Polls up to 318 devices on each loop in less than two seconds.
• Activates up to 159 outputs in less than five seconds.
• Multicolor LEDs blink device address during Walk Test.
• Fully digital, high-precision protocol (U.S. Patent 5,539,389).
• Manual sensitivity adjustment — up to nine levels.
• Pre-alarm ONYX intelligent sensing — up to nine levels.
• Sensitivity levels:
– Ion – 0.5 to 2.5%/foot obscuration.
– Photo – 0.5 to 2.35%/foot obscuration.
– Laser (VIEW®) – 0.02 to 2.0%/foot obscuration.
– Acclimate Plus™ – 0.5 to 4.0%/foot obscuration.
– IntelliQuad – 1.0 to 4.0%/foot obscuration.
– IntelliQuad™ PLUS – 1.0 to 4.0%/foot obscuration
• Drift compensation (U.S. Patent 5,764,142).
• Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515).
• Automatic detector sensitivity testing (NFPA-72 compliant).
• Maintenance alert (two levels).
• Self-optimizing pre-alarm.
• Programmable activation of sounder/relay bases during alarm or pre-alarm.
• Read Status displays the level of detector cleanliness.
FSL-751 VIEW® (VERY INTELLIGENT EARLY WARNING)
SMOKE DETECTION TECHNOLOGY
• Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524).
• Addressable operation pinpoints the fire location.
• Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost.
Relay Contact
NOTE: CPU2-3030 firmware version 14.0 (and higher) can support LCD-160 on the RDP port, or LCD2-80 in terminal mode, but not both at the same time. CPU2-3030D display or CPU2-3030ND PRN Series Printer NFS2-3030
Sample System Options
FAPT-851
FSL-751
FSP-851
FSA-8000
Shown in CAB-C4 with display DVC-EM audio in CA-1 in second tier LCD-160 LCD2-80 Up to 32
Remote Displays
EIA-485
EIA-485
SLC Intelligent Loop
3072 annunciator/control points
Optional 2048-point UDACT
Dual phone
lines to
Central
Station
EIA-232
DEVICES
ACM/AEM-24AT
LED Annunciator
LDM-32
Custom Graphics
ACM-8R
Relay Control
NBG-12LX XP6/10 I/O Modules
FMM-1
IDC
FWSG
DN-7070:P • 3/8/17 — Page 3 of 8
FAPT-851 ACCLIMATE PLUS™ LOW-PROFILE INTELLIGENT
MULTI-SENSOR
• Detector automatically adjusts sensitivity levels without
operator intervention or programming. Sensitivity increases
with heat.
• Microprocessor-based technology; combination photo and
thermal technology.
• Low-temperature signal at 40°F ± 5°F (4.44°C ± 2.77°C).
FSC-851 INTELLIQUAD
ADVANCED MULTI-CRITERIA DETECTOR
• Detects all four major elements of a fire (smoke, heat, CO, and flame).
• Automatic drift compensation of smoke sensor and CO cell.
• High nuisance-alarm immunity.
INTELLIGENT FAAST® DETECTORS FSA-5000, FSA-8000, FSA- 20000 AND FSA-20000P
• Connects directly to the SLC loop of compatible ONYX series panels.
• Provides five event thresholds that can be individually programmed with descriptive labels for control-by-event programming; uses five detector addresses.
• Uses patented particle separator and field-replaceable filter to remove contaminants.
• Advanced algorithms reject common nuisance conditions
• FSA-5000 covers 5,000 square feet through one pipe.
• FSA-8000 covers 8,000 square feet through one pipe.
• FSA-20000 covers 28,800 square feet through one to four pipes.
• FSA-20000P covers 28,800 square feet through one to four addressable pipes. Supports addressable pipes to pinpoint location of alarm events.
FCO-851 INTELLIQUAD™ PLUS
ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR
• Detects all four major elements of a fire.
• Separate signal for life-safety CO detection.
• Optional addressable sounder base for Temp-3 (fire) or Temp-4(CO) tone.
• Automatic drift compensation of smoke sensor and CO cell.
• High nuisance-alarm immunity.
FMM-4-20 GAS DETECTION MODULE
• Interface to industry-standard linear scale 4-20 mA sensors.
• Five programmable thresholds.
• FM Approved, Class 6320 (Stationary Gas Sensors/ Detectors).
SWIFT WIRELESS
• Self-healing mesh wireless protocol.
• Each SWIFT Gateway supports up to 50 devices: 1 wireless gateway and up to 49 SWIFT devices.
• Up to 4 wireless gateways can be installed with overlapping network coverage.
RELEASING FEATURES
• Ten independent hazards.
• Sophisticated cross-zone (three options).
• Delay timer and Discharge timers (adjustable).
• Abort (four options).
VOICE AND TELEPHONE FEATURES
• Up to eight channels of digital audio.
• 35 watt, 50 watt, 75 watt, and 100/125 watt digital amplifiers (DAA2/DAX series and DS series).
• Solid state message generation.
• Hard-wired voice control module options.
• Firefighter telephone option.
• 30- to 120-watt analog amplifiers (AA Series).
• Backup tone generator and amplifier option.